A rhythm strip is a measurement before it is a diagnosis. Read in a fixed sequence, the measurements lead to the name; read out of order, a flutter wave becomes a P wave and artifact becomes VT. This page sets out that order, the rhythms grouped by where they start, and the nursing work around them: alarms, pacing and a 12-lead placed where it should be.
Weight of each domain in the 125 scored items; filled squares mark where this topic draws from
IAssessment and Diagnosis (this topic draws on it)22 %
IIPlanning and Implementation (this topic draws on it)35 %
An IV amiodarone infusion is to continue for 24 hours after the loading dose. The cardiac-vascular nurse plans to give it through:
Choose an option; the reasons for all four open together.
Amiodarone irritates veins, so a long or concentrated infusion runs through a large or central vein with an in-line filter.
Push dosing belongs to pulseless arrest; a rhythm-control course is infused.
Small distal veins are the most likely to develop phlebitis with this drug.
Amiodarone does not need light protection while it runs, and standard tubing is acceptable; what a long infusion needs is a large or central vein and an in-line filter.
Show the key without choosing
Weight of each domain in the 125 scored items; filled squares mark where this topic draws from
IAssessment and Diagnosis (this topic draws on it)22 %
IIPlanning and Implementation (this topic draws on it)35 %
IIIEvaluation and Modification18 %
IVPatient and Community Education25 %
15 rhythm and device questions
Four answer choices per item; pick the best one.
Tally: 0 right, 0 tried, 15 in this set
Item 2 / 15 · EKG rhythms
A patient with a new implantable cardioverter-defibrillator (ICD) asks what to do if the device delivers one shock and they feel fine afterward. The cardiac-vascular nurse instructs the patient to:
A single shock followed by feeling well is reported the same day so the device and rhythm can be reviewed.
911 is for repeated shocks or a shock followed by chest pain, breathlessness or feeling unwell.
Waiting weeks leaves a possible new arrhythmia or device problem unreviewed.
Patients do not add doses on their own; resting is fine, but the extra pill is not.
Show the key without choosing
Item 3 / 15 · EKG rhythms
Which statement by a patient who received a permanent pacemaker yesterday indicates understanding of discharge teaching?
The arm on the implant side is kept below shoulder level for several weeks so the new leads do not pull loose.
Holding the phone to the ear on the opposite side keeps it a safe distance from the generator.
Household microwaves are safe with modern devices; avoiding them restricts the patient for no reason.
MRI is possible only with an MR-conditional system and a set protocol, not like anyone else.
Show the key without choosing
Item 4 / 15 · EKG rhythms
A patient on long-term amiodarone notices blue-gray discoloration of the face and burns easily in the sun. The cardiac-vascular nurse teaches the patient to:
Steroid cream does not reverse the pigment, and skin care is not the issue.
Sunscreen and protective clothing limit the photosensitivity and blue-gray color that build up on long-term amiodarone.
The discoloration is a skin deposit effect, not a sign of liver failure.
Stopping without an order risks the arrhythmia returning, and the color fades only slowly because the drug stays in tissue for months.
Show the key without choosing
Item 5 / 15 · EKG rhythms
A 76-year-old patient is evaluated for fainting spells. Which history finding most supports carotid sinus hypersensitivity?
Turning the head stretches the carotid sinus, which in hypersensitive older adults triggers a strong vagal response with slowing and vasodilation.
Fainting on exertion suggests an outflow obstruction such as aortic stenosis or an arrhythmia, a more dangerous pattern.
Faints after big meals fit postprandial hypotension, as blood pools in the gut.
A racing heart before a faint points toward a tachyarrhythmia.
Show the key without choosing
Item 6 / 15 · EKG rhythms
Which statement by a patient with a new implantable cardioverter-defibrillator (ICD) indicates understanding of device precautions?
Air travel is allowed; the patient shows the card and asks that a handheld wand not linger over the device.
The card lets airport staff and emergency teams know what is implanted and how to handle it.
Store security gates are safe to walk through at a normal pace; the patient just does not linger in them, so avoiding them restricts life for no reason.
Arc welding makes strong electromagnetic fields that gloves do not block.
Show the key without choosing
Item 7 / 15 · EKG rhythms
After several ICD shocks last month, a patient now avoids exercise and rarely leaves home for fear of another shock. The cardiac-vascular nurse's most appropriate intervention is to:
Restricting activity and travel deepens the avoidance and deconditioning the patient already has.
Anxiety and avoidance after shocks are common; counseling and peer support, along with a clear shock plan, reduce them.
No one can promise that; false reassurance breaks trust when the next shock comes.
Switching off the device removes protection against sudden death instead of treating the fear.
Show the key without choosing
Item 8 / 15 · EKG rhythms
A patient has had four unexplained fainting episodes over the past 6 months. The ECG, echocardiogram, and 24-hour Holter were normal. The cardiac-vascular nurse anticipates which next monitoring approach?
A stress test looks for exertional ischemia, not for an arrhythmic cause of random faints.
Another day of recording has the same poor odds of capturing an event that happens every month or two.
With faints months apart, only long-term monitoring is likely to catch one; an implanted recorder can link an episode to the rhythm for up to about 3 years.
Troponin shows myocardial injury, not the rhythm at the time of a faint.
Show the key without choosing
Item 9 / 15 · EKG rhythms
A patient with a new pacemaker is enrolled in remote monitoring. Which instruction does the cardiac-vascular nurse give?
The transmitter does not harm the device, and switching it off at night blocks the scheduled download.
Automatic transmissions catch lead or battery problems before symptoms appear.
Remote checks add to scheduled in-person visits; they do not replace them.
The transmitter often downloads the device overnight, so it must stay powered and within range of where the patient sleeps.
Show the key without choosing
Item 10 / 15 · EKG rhythms
A patient's 12-lead ECG shows a QRS of 0.14 seconds, a broad, deep, predominantly negative QRS in V1, and a broad notched R wave in V6. The cardiac-vascular nurse interprets this as:
Preexcitation has a short PR and a slurred delta wave at the start of the QRS.
A fascicular block shifts the axis to the left but keeps the QRS narrow.
Right bundle block shows an rSR' in V1 and a wide S wave in V6, the mirror of this tracing.
A QRS of 0.12 s or more, mostly negative in V1, with a broad notched R in V6 is the left bundle branch block pattern.
Show the key without choosing
Item 11 / 15 · EKG rhythms
A postoperative patient on telemetry has a new sinus tachycardia of 124/min. Temperature is 101.8°F (38.8°C), BP is 118/72 mm Hg, and the patient rates incisional pain 8/10. The cardiac-vascular nurse's best approach is to:
Slowing a compensatory sinus rate with a beta-blocker hides the cause and can drop blood pressure.
Sinus tachycardia is usually a response to something, here fever and pain, so treating those causes is what slows it.
Adenosine is for reentrant SVT; mistaking a sinus rhythm for SVT is the error behind this choice.
Cardioversion does not work for sinus tachycardia and is meant for unstable reentrant rhythms.
Show the key without choosing
Item 12 / 15 · EKG rhythms
A patient going home with a new permanent pacemaker programmed to a lower rate of 60/min is taught to check the pulse. Which finding should the patient report?
A normal resting rate above the set lower limit needs no report.
The heart rate is expected to rise with activity, either on its own or through rate response.
A pulse below the programmed lower rate of 60/min can mean a battery or lead problem, so it is reported.
A rate just above the set lower limit is the device doing its job.
Show the key without choosing
Item 13 / 15 · EKG rhythms
A patient with recurrent vasovagal syncope asks what to do when the familiar warning signs of warmth and nausea begin. The cardiac-vascular nurse's best instruction is:
Lowering the body and tensing crossed legs or gripping the hands raise blood pressure and can abort a reflex faint.
Walking while lightheaded risks falling, and the faint comes from vasodilation, not a slow pace.
Staying upright keeps blood pooled in the legs, so the faint and a fall may still happen.
Coffee works too slowly to stop a faint that is minutes away.
Show the key without choosing
Item 14 / 15 · EKG rhythms
A patient admitted for low-risk chest pain has been on telemetry for 48 hours. Serial troponins and a stress test are negative, and no arrhythmias have been recorded. The cardiac-vascular nurse should:
A Holter answers a different question and is not a step down from inpatient telemetry.
Stopping ordered monitoring still needs an order; the nurse raises the question rather than acting alone.
Telemetry is ordered for an indication and a time frame; once the low-risk workup is negative, the nurse prompts a review rather than monitoring by habit.
Monitoring without an indication adds false alarms and limits mobility without helping the patient.
Show the key without choosing
Item 15 / 15 · EKG rhythms
A patient with permanent atrial fibrillation takes digoxin, has a level in the target range and no symptoms. The 12-lead shows a ventricular rate of 72/min and sagging, downsloping ST depression in the lateral leads, unchanged from last month. The cardiac-vascular nurse recognizes this as:
An unchanged tracing in a patient without symptoms is not an evolving infarction; reading every ST sag as ischemia is the trap.
Toxicity is judged by symptoms, the level and new rhythms such as heart block or bigeminy; this stable tracing alone does not call for the antidote.
Digoxin does not lower potassium; a low level in a patient like this usually comes from a diuretic.
The "reverse tick" ST sag appears at therapeutic digoxin levels; with a level in range, no symptoms and a stable tracing, it marks the drug, not a dangerous excess.
Show the key without choosing
–/15
Your tally for this page
Kept in this tab alone: closing or refreshing the tab wipes it.
Rate. On a regular rhythm, count the large boxes from one R wave to the next and divide 300 by that number; on any rhythm, multiply the QRS complexes in 6 seconds by 10.
Regularity. March out the R-R intervals with calipers or a paper edge.
P waves. Present, upright in lead II, one before every QRS?
PR interval. Normal lies between 0.12 and 0.20 seconds, and it should not change from beat to beat.
QRS width. Under 0.12 seconds is narrow; at 0.12 or more the impulse is traveling slowly or outside the normal pathway.
QT interval. Measured from QRS onset to the point where the T wave returns to baseline, then corrected for rate; the unit's protocol names the formula. Use a lead where the T wave's end is easy to see, and keep to that lead.
ST segment and T wave. Elevation, depression or inversion compared with the patient's earlier strips.
The patient. Name the rhythm, then look at the person: the same rhythm can be tolerated well or not at all.
One box on standard paper is 0.04 seconds; one large box is 0.20 seconds. Those two numbers carry every interval above. The outline mentions rhythms only once, as an example of data interpretation under I.B.3; this order is how that interpretation gets done at the bedside.
Rhythms by where they start
Sinus
Sinus rhythm, sinus bradycardia (under 60/min), sinus tachycardia (over 100/min) and sinus arrhythmia, which speeds and slows with breathing.
Atrial
Premature atrial complexes; atrial flutter, with its sawtooth flutter waves at about 300/min and a ventricular rate set by the block ratio; multifocal atrial tachycardia, with three or more P-wave shapes. A steady rate near 150/min that never varies can be flutter with 2:1 block, a second flutter wave buried in the T wave. Atrial fibrillation is covered in depth on atrial fibrillation.
Junctional
An impulse from the AV junction: P waves inverted in lead II, hidden in the QRS or just after it, and an intrinsic rate of 40 to 60/min.
Ventricular
Premature ventricular complexes, wide and bizarre, with a compensatory pause; ventricular tachycardia, a run of at least three consecutive wide complexes; ventricular fibrillation, chaotic with no QRS; idioventricular rhythm at 20 to 40/min. Asystole and pulseless electrical activity are diagnosed at the bedside, not on the screen alone.
First-degree: PR longer than 0.20 seconds, every P conducted.
Second-degree, Mobitz I (Wenckebach): the PR grows with each beat until a P wave fails to conduct, and then the cycle starts again. The block is usually in the AV node.
Second-degree, Mobitz II: a fixed PR with P waves that suddenly fail to conduct. The block is usually below the node and can progress without warning to complete block.
Third-degree (complete): P waves and QRS complexes march at their own rates with no relationship; the escape rhythm is junctional (narrow) or ventricular (wide and slow).
A 2:1 block cannot be labeled Mobitz I or II from that stretch alone, because there are no two conducted PR intervals in a row to compare.
Fast rhythms: SVT, VT and torsades
Supraventricular tachycardia
Narrow QRS complexes at a fast, regular rate, often 150 to 250/min, with P waves hidden or seen just after the QRS. The 2015 ACC/AHA/HRS SVT guideline (2015) starts with vagal maneuvers and then IV adenosine in a stable patient. Adenosine is given as a rapid push into a proximal vein, chased at once by a saline flush; a few seconds of asystole, flushing and chest pressure are expected, and the patient is warned before the push. The strip is recorded throughout, because what the rhythm does as it slows can reveal flutter waves that were hidden.
Ventricular tachycardia
Wide-complex, usually regular. Whether the patient has a pulse decides everything that follows, which is why the nurse checks the patient before the monitor.
Torsades de pointes
Polymorphic VT whose QRS axis twists around the baseline, on a background of a long QT interval. QT-prolonging drugs, low potassium or magnesium, and bradycardia set it up, so a baseline QT on record before such a drug starts is part of the order set.
One cost of bedside monitoring is alarms nobody trusts. In a study of 461 ICU patients, Drew and colleagues (PLoS One, 2014) reviewed more than 12,000 arrhythmia alarms and found 88.8% of them false. The authors traced the excess to alarm settings that did not fit the patient, persistent atrial fibrillation, events that needed no action, low-amplitude QRS complexes in some leads, and wide QRS complexes from bundle branch block or ventricular pacing that the software miscounted. Several of those causes sit within the nurse's reach: a monitoring lead with a clear, tall QRS, and alarm limits set for the patient in front of the monitor rather than left on defaults. An alarm silenced without finding its cause, such as a loose electrode, can hide the moment the rhythm really changes.
Pacing codes and pacemaker malfunction
The NASPE/BPEG generic pacemaker code (2002) describes a mode in up to five letters: chamber paced, chamber sensed, response to sensing (I = inhibited, T = triggered, D = dual), rate modulation (R) and multisite pacing. DDD paces and senses both chambers; VVI paces and senses the ventricle and holds back when the heart beats on its own.
Four patterns to recognize on a paced strip:
Failure to capture: a pacing spike with no P wave or QRS after it.
Failure to pace: no spike where the programmed rate says one is due.
Undersensing: spikes that land on or near the patient's own beats, because the device did not see them.
Oversensing: pauses, because the device read noise or muscle activity as a beat and held back.
V1 and V2: the fourth intercostal space, just right and just left of the sternum.
V4: the fifth intercostal space where it crosses the midclavicular line.
V3: halfway along the line from V2 to V4.
V5 and V6: on the horizontal plane of V4, at the anterior axillary and the midaxillary lines.
The same document warns that arm and leg electrodes placed on the chest wall, as bedside monitors place them, change the tracing, so a diagnostic 12-lead is taken with them on the limbs. In women the precordial electrodes go beneath the breast, not on it. V1 and V2 put one or two spaces above the fourth intercostal space are a frequent error, and they alter the right precordial complexes. Right-sided leads, such as V4R, are added when the provider asks for them.
Two that are not limited to nurses: the CEPS exam (allied professional electrophysiology specialist) from the International Board of Heart Rhythm Examiners (IBHRE), and the RCES exam (Registered Cardiac Electrophysiology Specialist) from Cardiovascular Credentialing International (CCI). Both are aimed at the electrophysiology lab rather than bedside telemetry.